利用漏磁辐射的非接触式开关电源稳定性探测方法

Non-Contact Detecting Method of the Stability of Switching Power by Using Magnetic Leakage Radiation

  • 摘要: 为解决开关电源稳定性测试繁琐的问题,提出一种针对开关电源稳定性进行定性分析的非接触式测试方法。首先讨论了开关电源闭环模型稳定性准则、线圈耦合模型及修正等问题,然后分析了利用探测线圈对开关电源磁性元件的漏磁辐射进行探测的原理,说明通过对探测信号进行放大、变换和信号处理,能够获得可反映电源工作稳定性的信息。通过试验验证了该方法的有效性。

     

    Abstract: Aiming at solving the problem of the complicated tests of the stability of switching power supplies, a non-contact testing method of qualitative analysis for the stability of switching power supplies is presented. Several issues are discussed, including the stable principles of switching power closed-loop model, the coil model, and the radiation signal processing, etc. Coil is utilized to detect magnetic leakage radiation of magnetic elements of switching power, and the stability working information of switching power supplies is achieved via amplifying, transmitting and processing of the radiation signals. The validity of the methodology is verified by experiments.

     

/